According to European standard EN13155, vacuum lifters intended for use on construction sites must either be equipped with the secondary gripping device (slings) or be equipped with a dual vacuum circuit, meaning a dual system complete with vacuum reservoir and non-return valves. Each vacuum reservoir must be connected to a separate set of suction cups.
Why is this so important?
Because it is one of the main elements in preserving the operator’s health and the load safety. Each cross-pair of suction cups is connected to a single vacuum circuit, effectively making these pairs independent. This allows, in the event of malfunctions or power failures in one vacuum circuit, its opposite circuit to always be functioning, ensuring load holding and safety for the operator (who will then have time to secure the load and the team).